industrial ups for data center
"
CMA 25KW 30KW 35KW 40KW 45KW 50KW Server Room Air Conditioner for Lab and Data Center
Product Description Specification Room-level precision air conditioning technical parameters and configuration table (single system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA1025UCMA1030UCMA1035UCMA1040UOutdoor unit modelCMT025SPCMT040SPCMT045SPCMT050SPEnergy efficiency ratio3.013.093.053.01Power Specifications380VAC/50HZMaximum current26A35A39A42ARecommended input space40A/4P50A/4P63A/4P63A/4PCooling capacity (kW20.230.535.440.2Sensible
5000m3/h Visench CRA 12.5KW Server Room Precision Air Conditioner for Lab Data Center
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw252540.3Sensible cooling capacity (kw252540.3sensible
Visench CRA 12.5KW 25KW 40KW 50KW 60KW Room-Based Air-Cooled Precision Air Conditioner for Lab Data Center
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw252540.3Sensible cooling capacity (kw252540.3sensible
Visench Fortress 60KVA 80KVA 100KVA 120KVA 180KVA 200KVA 240KVA 300KVA Online UPS For Networking
Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion 2% THD (Linear Load); 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**
Mounting Floor Standing Industrial Air Conditioner for Lab Server Room and Data Center
Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm5*2.5mmOutdoor unit cable (recommended)3*1mmInner and outer unit signal cables (recommended)noneCooling capacity (kW813Sensible cooling
380VAC Visench CMA2040U Dual System Air Cooling Industrial Precision Air Conditioner R410 EC Fan For Data Center Room
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW40.450.660.4Sensible cooling capacity (kW3746.355.1sensible heat
Data Center Visench Galleon III 3 Phase Pure Sine Wave OEM UPS Rated Capacity 10KVA-40KVA
Product nameGalleon III 3p3pRated Capacity10KVA-40KVAPower Factor0.99Input Voltage3 x 360/380/400/415 VAC(3Ph+N)Frequency40~70 HZOutput Voltage3 x 360*1380*/400/415 VAC (3Ph+N)WaveformPure Sine waveBattery Type12V/9AhPHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph outHarmonic Distortion 2% THD (Linear Load) ; 5 % THD (Non-inear Load)Current Crest Ratio3:1(max.)Battery Mode94.50%Frequency Range46~54Hz or 56~64HzInverter to BypassZeroOperating Temperature0-40CSize(mm
3 Phase Galaxy VX UPS 500kVA 500kW 400V For Large Data Center
Features 500 to 1500kW N+1 The Schneider Electric Galaxy VX UPS is a scalable, high-performance extension of the Galaxy V-Series solutions, designed for large data center and industrial applications: Lower your energy costs and meet changing business requirements, with 99% efficiency in ECOnversion mode. Provide excellent power quality in demanding electrical environments. Install and deploy your UPS quickly. Manage your power anywhere. Galaxy VX supports local and remote
APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V
Features 500 to 1500kW N+1 The Schneider Electric Galaxy VX UPS is a scalable, high-performance extension of the Galaxy V-Series solutions, designed for large data center and industrial applications: Lower your energy costs and meet changing business requirements, with 99% efficiency in ECOnversion mode. Provide excellent power quality in demanding electrical environments. Install and deploy your UPS quickly. Manage your power anywhere. Galaxy VX supports local and remote