APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V

Place of Origin China
Brand Name APC
Certification CE EAC RCM
Model Number GVX1000K1000NHS
Minimum Order Quantity 1
Payment Terms L/C, D/A, D/P, T/T

Contact me for free samples and coupons.

WhatsAPP:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Lead Time Special Order - Call For Quoted Lead Times Main Input Voltage 400 V 3 Phases
Other Input Voltage 380 V 415 V Other Output Voltage Other Output Voltage
Battery Voltage +/- 216...+/- 300 V Weight 688 Kg
Dimensions 2117 X 1000 X 800 Mm Topology Double Conversion Online
Efficiency Up To 96% Display LCD
Communication Ports USB, RS232, SmartSlot Frequency 50/60Hz
Form Factor Tower
Highlight

Galaxy VX UPS 1000kW 400V

,

Galaxy VX UPS 1000kVA

You can tick the products you need and communicate with us in the message board.
GVX500K500NHS 500 kVA/500 kW
GVX625K625NHS 625 kVA/625 kW
GVX750K750NHS 750 kVA/750 kW
GVX800K800NHS 800 kVA/800 kW
GVX1000K1000NHS 1000 kVA/1000 kW
GVX1100K1100NHS 1100 kVA/1100 kW
GVX1250K1250HS 1250 kVA/1250 kW
GVX1500K1500HS 1500 kVA/1500 kW
Leave a Message
GVX500K500NHS 500 kVA/500 kW
Product Description

Features

500 to 1500kW N+1
The Schneider Electric Galaxy VX UPS is a scalable, high-performance extension of the Galaxy V-Series solutions, designed for large data center and industrial applications:
  • Lower your energy costs and meet changing business requirements, with 99% efficiency in ECOnversion mode.
  • Provide excellent power quality in demanding electrical environments.
  • Install and deploy your UPS quickly.
  • Manage your power anywhere. Galaxy VX supports local and remote communication via touchscreen, Web interface, Modbus, and the Schneider Electric StruxureWare for Data Center Expert solution.

Benefits

Availability Serviceability
  • StruxureOn enabled - Simplify maintenance and operation of your equipment through the use of vendor-neutral, cloud-based software and services.
  • Multiple levels of service - With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like APC to do for you.
  • StruxureWare Data Center Expert compatible - Enables centralized management via StruxureWare Data Center Expert.
  • Front-access servicing - Simplifies installation and UPS maintenance while minimizing space requirements.
  • 5x8 Start-up service included - Required for full coverage of factory warranty
Total cost of Ownership
  • Wide input voltage range - Designed for harsh electrical environments to save battery life.
  • ECOnversion mode - Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
  • Input Power Factor Correction - Minimizes installation costs by enabling the use of smaller generators and cabling.
  • ECO Mode - Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
  • Robust operation - No power derating in kW up to 40 degrees C or 104 degrees F.

Specifications

 

Overview
Presentation A highly efficient, modular, 1000 kVA 3-phase UPS that provides the performance, flexibility, and maximized asset utilization today’s large data centers and mission critical applications require. This EcoStruxure connected UPS features up to 99% efficiency with patented eConversion technology. Includes 5x8 start-up service.
Lead time Special Order - Call for Quoted Lead Times

Main
Main Input Voltage 400 V 3 phases
Other Input Voltage 380 V
415 V
440 V
Main Output Voltage 400 V 3 phases
Other Output Voltage 380 V
415 V
440 V
Rated power in W 1000 kW
Rated power in VA 1000 kVA
Battery type External battery system
Provided equipment Installation guide
Start-up service

Batteries & Runtime
Efficiency View Efficiency Graph
action_new_window
Battery voltage 480 V
Discharge battery voltage 384 V DC
Battery power in VAH 0 VAh runtime
Extended runtime 0

General
Redundant No

Physical
Colour White
height 197 cm
Width 360 cm
Depth 90 cm
Net weight 3110 kg
USB compatible No

Input
Network frequency 40...70 Hz
Maximum input current 1702 A
Max short time withstand current 100 kA
Input harmonic distortion Less than 3 % for full load
Load power factor From 0.7 leading to 0.5 lagging without any derating

Output
Maximum configurable power in W 1000 kW
Output frequency 50 Hz sync to mains
60 Hz sync to mains
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
Crest factor 3 with THC <5%
Wave type Sine wave
Output harmonic distortion < 2% linear load and < 3% non-linear load
Output overload operation 10 minutes at 125% and 60 seconds at 150%
Maximum configurable power in VA 1000 kVA

Conformance
product certifications cUL listed
C-Tick
CE
UL 1778 5th edition
Standards ETL
IBC 2012
IEC 62040-1-1
IEC 62040-2
IEC 62040-3
IEC 62040-4
ISTA 2B

Environmental
ambient air temperature for operation 0…40 °C
Relative humidity 0…95 % non-condensing
Operating altitude 0...3333 ft
Ambient air temperature for storage -15…40 °C
Storage Relative Humidity 0…95 % non-condensing
Storage altitude 0.00…15240.00 m
Acoustic level 69.5 dBA
heat dissipation 175802 Btu/h
IP degree of protection IP20

Communications & Management
Free slots 2
control panel 7" touch screen display

Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 215 cm
Package 1 Width 106 cm
Package 1 Length 465 cm
Package 1 Weight 4680 kg

Contractual warranty
Warranty 1 year on-site repair or replace with factory authorized Start-Up

APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 0APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 1APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 2APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 3APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 4APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 5APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 6APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 7APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 8APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 9APC Data Center And Facility 3 Phase Galaxy VX UPS 1000kVA 1000kW 400V 10