santak ups
"
EATON FLEXPDU BASIC 1U C14 10A 1P 12XC13 The Must-Have PDU for Monitored Data Centers
CategaryModelDerated AMPPhaseInput VoltageOutlet TypesCircuit breakerSizeW*D*H(MM)SpecsMonitoredEMIB0016A3PIEC 309 16A 3P36C13:6C19-52*53*18290UEMIB0310A1PC14 10A 1P6C13-52*53*10700UEMIB0416A1PIEC60309 16A 1P20C13:4C19-52*53*10700UEMIB0532A1PIEC60309 32A 1P20C13:4C1921P52*53*11540UEMIB0632A1PIEC60309 32A 1P12C13:4C1921P52*53*10700UEMIB0732A1PIEC60309 32A 3P6C13:12C1961P52*53*16040UEMIB0832A1PIEC60309 32A 1P36C13:6C1921P52*53*16040UEMIB0916A1PC20 16A 1P18C13
Eaton ATS Load Switching Switch 10A 16A 32A Frame Current 1 EATS30N for Data Center
TECHNICAL SPECIFICATIONSATS 16ATS 16 NetpackATS 30Nominal current16A16A30A*Input/outputNominal voltage/input frequency208/220/230/240 V ; 50/60HzPerformanceTypical transfer time8 msSafetyIEC/EN 62310-1,IEC/EN 60950-1IEC/EN 62310-1,IEC/EN 60950-1IEC/EN 60950-1EMCIEC/EN 62310-2MarkingCEConnectionInputs2IEC C20 + 2 input cablesHardwiredOutputs8 IEC C13 + 1 IEC C19HardwiredCommunication and user interfaceUser interfaceLCDLEDNetwork communicationNoYesDimensions and weightDimension
Intelligent PDU for Power Data Centers EATON EFLXB21 FLEXPDU BASIC 0U C20 16A 1P 16XC13
CategaryModelDerated AMPPhaseInput VoltageOutlet TypesCircuit breakerSizeW*D*H(MM)SpecsMonitoredEMIB0016A3PIEC 309 16A 3P36C13:6C19-52*53*18290UEMIB0310A1PC14 10A 1P6C13-52*53*10700UEMIB0416A1PIEC60309 16A 1P20C13:4C19-52*53*10700UEMIB0532A1PIEC60309 32A 1P20C13:4C1921P52*53*11540UEMIB0632A1PIEC60309 32A 1P12C13:4C1921P52*53*10700UEMIB0732A1PIEC60309 32A 3P6C13:12C1961P52*53*16040UEMIB0832A1PIEC60309 32A 1P36C13:6C1921P52*53*16040UEMIB0916A1PC20 16A 1P18C13
Eaton ATS 30A Dual Power Static Switching Switch Automatic Transfer 3 Pole IEC C13
TECHNICAL SPECIFICATIONSATS 16ATS 16 NetpackATS 30Nominal current16A16A30A*Input/outputNominal voltage/input frequency208/220/230/240 V ; 50/60HzPerformanceTypical transfer time8 msSafetyIEC/EN 62310-1,IEC/EN 60950-1IEC/EN 62310-1,IEC/EN 60950-1IEC/EN 60950-1EMCIEC/EN 62310-2MarkingCEConnectionInputs2IEC C20 + 2 input cablesHardwiredOutputs8 IEC C13 + 1 IEC C19HardwiredCommunication and user interfaceUser interfaceLCDLEDNetwork communicationNoYesDimensions and weightDimension
24 Way EATON EFLXB22 FLEXPDU BASIC 0U C20 16A 1P 20XC13 4XC19 Monitored PDU
CategaryModelDerated AMPPhaseInput VoltageOutlet TypesCircuit breakerSizeW*D*H(MM)SpecsMonitoredEMIB0016A3PIEC 309 16A 3P36C13:6C19-52*53*18290UEMIB0310A1PC14 10A 1P6C13-52*53*10700UEMIB0416A1PIEC60309 16A 1P20C13:4C19-52*53*10700UEMIB0532A1PIEC60309 32A 1P20C13:4C1921P52*53*11540UEMIB0632A1PIEC60309 32A 1P12C13:4C1921P52*53*10700UEMIB0732A1PIEC60309 32A 3P6C13:12C1961P52*53*16040UEMIB0832A1PIEC60309 32A 1P36C13:6C1921P52*53*16040UEMIB0916A1PC20 16A 1P18C13
AC 220V 3 Pole Eaton ATS EATS30N Automatic Transfer Switch for C19 Redundant Power PDU
TECHNICAL SPECIFICATIONSATS 16ATS 16 NetpackATS 30Nominal current16A16A30A*Input/outputNominal voltage/input frequency208/220/230/240 V ; 50/60HzPerformanceTypical transfer time8 msSafetyIEC/EN 62310-1,IEC/EN 60950-1IEC/EN 62310-1,IEC/EN 60950-1IEC/EN 60950-1EMCIEC/EN 62310-2MarkingCEConnectionInputs2IEC C20 + 2 input cablesHardwiredOutputs8 IEC C13 + 1 IEC C19HardwiredCommunication and user interfaceUser interfaceLCDLEDNetwork communicationNoYesDimensions and weightDimension
20 Way EATON EFLXB10 FLEXPDU BASIC 0U 309 16A 1P 18XC13 2XC19 Power Distribution Unit
CategaryModelDerated AMPPhaseInput VoltageOutlet TypesCircuit breakerSizeW*D*H(MM)SpecsMonitoredEMIB0016A3PIEC 309 16A 3P36C13:6C19-52*53*18290UEMIB0310A1PC14 10A 1P6C13-52*53*10700UEMIB0416A1PIEC60309 16A 1P20C13:4C19-52*53*10700UEMIB0532A1PIEC60309 32A 1P20C13:4C1921P52*53*11540UEMIB0632A1PIEC60309 32A 1P12C13:4C1921P52*53*10700UEMIB0732A1PIEC60309 32A 3P6C13:12C1961P52*53*16040UEMIB0832A1PIEC60309 32A 1P36C13:6C1921P52*53*16040UEMIB0916A1PC20 16A 1P18C13
Max. Current 32A 230V C19 VERTIV Liebert STS Static Transfer Switch UF-LTS32-1P IP11
Items(10A, 16A) Specifications (32A) SpecificationsInputInput sourceTwo AC inputsInput mode1+N+PERated voltage220/230VacRated frequency50/60HzVoltage range150~300VacFrequency rangeRated frequency5HzVoltage distortion
24 Way EATON EFLXB05 FLEXPDU BASIC 0U 309 32A 1P 20XC13 4XC19 CB Data Center PDU
CategaryModelDerated AMPPhaseInput VoltageOutlet TypesCircuit breakerSizeW*D*H(MM)SpecsMonitoredEMIB0016A3PIEC 309 16A 3P36C13:6C19-52*53*18290UEMIB0310A1PC14 10A 1P6C13-52*53*10700UEMIB0416A1PIEC60309 16A 1P20C13:4C19-52*53*10700UEMIB0532A1PIEC60309 32A 1P20C13:4C1921P52*53*11540UEMIB0632A1PIEC60309 32A 1P12C13:4C1921P52*53*10700UEMIB0732A1PIEC60309 32A 3P6C13:12C1961P52*53*16040UEMIB0832A1PIEC60309 32A 1P36C13:6C1921P52*53*16040UEMIB0916A1PC20 16A 1P18C13