DELTA Ultron DPM Gen2 Series Modular UPS 250-1750 KVA 380V Three-phase with 250kw Power Module for Data Centers
DELTA Ultron DPM Gen2 Series Modular UPS 250-1750 KVA 380V Three-phase with 250kw Power Module. Features >0.99 input power factor, <3% current harmonic distortion, and robust overload capability. Supports parallel operation up to 8 units, compatible with multiple battery types (VRLA, Lithium-ion), and certified with CE/UL safety standards. Designed specifically for AI data centers.
250-1750 KVA Modular UPS
,380V Three-phase UPS System
,250kw Power Module Uninterruptible Power Supply
| Specification | Value |
|---|---|
| Place of Origin | China |
| Brand Name | DELTA |
| Model Number | DPM G2-1750K |
| Electric Energy | 100Wh |
| Battery Type | Lead Acid Battery |
| Phase | Three Phase |
| Protection | Short Circuit |
| Weight | 2836.3 kg |
| Type | On-line |
| Application | Data Center |
| Parallel Operation | Up to 8 units |
| Input Power Factor | > 0.99 (100% load) |
| Current Harmonic Distortion | < 3% (100% resistive load) |
| Output Overload Capability | 110-125%: 10 mins; 126-150%: 1 min; > 150%: 1 sec |
| Output Frequency | 50/60 Hz ± 0.5 Hz |
| External Battery Compatible Type | VRLA, Vented lead-acid, Lithium-ion, Ni-Zinc |
| Battery Voltage | 480 Vdc |
| Safety | CE, UL |
- Precision air conditioning & liquid cooling systems
- UPS batteries & integrated battery energy storage
- Power distribution systems (PDU, switchgear, busway)
- Modular Data Centers (MDC)
- Power modules & containerized data centers
- Solid-State Transformers (SST)
Hot Aisle Containment (HAC): Hot air exhausted from cabinet rears is sealed within the contained aisle and channeled back to AC through ceiling or return air ducts. Advantages: Theoretically higher cooling efficiency. Disadvantages: Requires the entire room to be kept at low temperature and certain ceiling height, ideal for large or hyperscale data centers.
Accepted Payment Currency: USD, EUR, JPY, CAD, AUD, HKD, GBP, CNY, CHF
Accepted Payment Type: T/T, L/C, D/P D/A, , Credit Card, PayPal, Western Union, Cash, Escrow
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, Arabic, French, Russian
-
Delta Amplon RT Gen3 1-3KVA Single-phase Rack UPS with LCD Display for Networking
Delta Amplon RT Gen3 1-3KVA rack UPS delivers pure sine wave power with <3% THDi. Online double-conversion ensures zero transfer time, while LCD display and multiple ports provide comprehensive monitoring. Compact design with robust overload protection for critical networking equipment.
-
Delta Amplon N Gen3 Series 1-3KVA Single-phase On-line Double-conversion UPS with LCD Display for Networking
Delta Amplon N Gen3 1-3KVA online UPS with double-conversion technology, <3% THDi, and LCD display. Features 4x IEC C13 ports, USB/RS-232 connectivity, and robust overload protection. Compact design for reliable network power backup.
-
DELTA Modulon DPH Gen3 Series UPS 125-2000 KVA Three-phase Modular Uninterruptible Power Supply for Data Centers
DELTA Modulon DPH Gen3 Series UPS: Three-phase 125-2000 KVA 400V UPS with 125kw power modules, designed for data centers. Features high efficiency (>0.99 input PF), ultra-low THDi (<2%), flexible battery options (VRLA/Lithium-ion), and supports up to 8 power modules. Offers robust overload protection and multiple communication protocols (SNMP, Modbus, HTTP(S)).