DELTA Modulon DPH Gen3 Series UPS 125-2000 KVA Three-phase Modular Uninterruptible Power Supply for Data Centers
DELTA Modulon DPH Gen3 Series UPS: Three-phase 125-2000 KVA 400V UPS with 125kw power modules, designed for data centers. Features high efficiency (>0.99 input PF), ultra-low THDi (<2%), flexible battery options (VRLA/Lithium-ion), and supports up to 8 power modules. Offers robust overload protection and multiple communication protocols (SNMP, Modbus, HTTP(S)).
125-2000 KVA UPS
,Three-phase Uninterruptible Power Supply
,Data Center Modular UPS
| Specification | Value |
|---|---|
| Place of Origin | China |
| Brand Name | DELTA |
| Model Number | DPH-G3-2000K-MD |
| Electric Energy | 100Wh |
| Battery Type | Lithium Battery |
| Phase | Three Phase |
| Protection | Short Circuit |
| Weight | 915 kg |
| Type | On-line |
| Application | Data Center |
| Power Module Quantity | Up to 8 units |
| Input Power Factor | > 0.99 (100% load) |
| Output Frequency | 50/60 ± 0.05 Hz |
| Total Harmonic Distortion (THDi) | < 1.5% (linear load); < 2% (non-linear load) |
| Output Overload Capability | < 110%: continuously; ≤ 125%: 10 min; ≤ 150%: 1 min |
| Battery Type | VRLA/Lithium-ion |
| Nominal Voltage | 480 Vdc |
| Port | RS-232, RS-485, USB, RJ45, REPO |
| Protocols | SNMP, Modbus, HTTP(S) |
- Precision air conditioning & liquid cooling systems
- UPS batteries & integrated battery energy storage
- Power distribution systems (PDU, switchgear, busway)
- Modular Data Centers (MDC)
- Power modules & containerized data centers
- Solid-State Transformers (SST)
Traditional Data Center: Like "building a house on-site." Equipment from various manufacturers is pieced together, requiring massive engineering work, a long construction cycle (typically 3 to 6 months), and resulting in a higher PUE.
Modular Data Center: Like "building with Lego blocks." It features full factory pre-fabrication and rapid on-site assembly, enabling delivery in as fast as 1 to 2 weeks. By utilizing contained aisles and in-row air conditioners, its cooling efficiency is extremely high, significantly reducing operational electricity costs.
In-Row Air Conditioning: AC units are placed right next to the servers, blowing cold air at close range.
Aisle Containment: Completely segregates the cold air from the hot air exhausted by the servers (e.g., creating a Cold Aisle Containment). This ensures that 100% of the cold air flows through the servers without wasting electricity, helping cut down data center AC-specific electricity bills by approximately 30% to 40%.
Advantages: Low requirements for the overall data center room environment. Suitable for the vast majority of newly built or retrofitted data centers.
Hot Aisle Containment (HAC): The hot air exhausted from the rear of cabinets is sealed within the contained aisle and channeled back to the AC.
Advantages: Cooling efficiency is theoretically higher than CAC. Disadvantages: Requires the entire room to be kept at low temperature and certain ceiling height, making it ideal for large or hyperscale data centers.
Real-World Scenario: When the building's fire alarm system detects a fire signal, the monitoring system instantly and automatically releases the modular data center's overhead roof panels, allowing external fire suppression gas to flood the aisle and extinguish the fire. Concurrently, it handles audio-visual alarms, mobile APP push notifications, and outlet-level/rack-level PDU power monitoring, making it the absolute core for ensuring safety of unmanned, lights-out data centers.
Accepted Payment Currency: USD, EUR, JPY, CAD, AUD, HKD, GBP, CNY, CHF
Accepted Payment Type: T/T, L/C, D/P D/A, , Credit Card, PayPal, Western Union, Cash, Escrow
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, Arabic, French, Russian
-
Delta Amplon RT Gen3 1-3KVA Single-phase Rack UPS with LCD Display for Networking
Delta Amplon RT Gen3 1-3KVA rack UPS delivers pure sine wave power with <3% THDi. Online double-conversion ensures zero transfer time, while LCD display and multiple ports provide comprehensive monitoring. Compact design with robust overload protection for critical networking equipment.
-
Delta Amplon N Gen3 Series 1-3KVA Single-phase On-line Double-conversion UPS with LCD Display for Networking
Delta Amplon N Gen3 1-3KVA online UPS with double-conversion technology, <3% THDi, and LCD display. Features 4x IEC C13 ports, USB/RS-232 connectivity, and robust overload protection. Compact design for reliable network power backup.
-
DELTA Ultron DPM Gen2 Series Modular UPS 250-1750 KVA 380V Three-phase with 250kw Power Module for Data Centers
DELTA Ultron DPM Gen2 Series Modular UPS 250-1750 KVA 380V Three-phase with 250kw Power Module. Features >0.99 input power factor, <3% current harmonic distortion, and robust overload capability. Supports parallel operation up to 8 units, compatible with multiple battery types (VRLA, Lithium-ion), and certified with CE/UL safety standards. Designed specifically for AI data centers.