Medical Backup Battery Power Supply Online UPS High Frequency Pure Sine Wave Uninterrupted Tower Ups System

Contact me for free samples and coupons.
WhatsAPP:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xFrequency | 50/60Hz | Output Voltage | 220/230/240VAC |
---|---|---|---|
Overload Capacity | 111–125%: 10 Mins, 126–150%: 1 Minute | Weight | Depends On The Power Range |
Operating Temperature | 0~40℃ | Rated Capacity | 1KVA -10KVA |
Battery Voltage | 24VDC/36VDC/48VDC/72VDC/96VDC | Input Voltage | 220/230/240VAC |
Altitude | ≤ 1000m | Humidity | 20-90% |
Protection | Overload, Short Circuit, Over Voltage, Low Voltage, Over Temperature | Battery Quantity | Internal: 8/10/12pcs, External: Up To 4 Strings |
Online Mode | 96% | Power Range | 1-20kVA |
Dimension | Depends On The Power Range |
High Frequency Online UPS
XT Series (three-three phase)
PRODUCT FEATURES
1. Advanced DSP digital control to make the control system more stable and reliable.
2. Double transform on-line design, adopting power factor coorrection (PFC) technology, input power factor is up to 0.9
3. Output power factor is 0.9(0.8 is available optional),with higher actual load capacity to save users' investiment.
4. intelligent charging management, ±16-±20pcs(32-40pcs) batteries to select.
5. Plentiful options, USB or RS485 communication interface, SNMP card (optional), parallel board (optional).
6. ECO working mode,high efficiency and energy saving reduce users' cost.
7. Parallel redundancy function, it enables to connect 4 units in parallel, and the battery pack can be shared in parallel.
8. Four modes (three phase ,three-single phase,single-three phase, single phase)
PARAMETER XT33 60-80KVA | |||
Model | XT33 60KS | XT33 80KS | |
Rated Power | 60kVA/54kW | 80kVA/72kW | |
Input | Voltage Range | 208-478Vac 3P4W+G | |
Working Frequency Range | 45-55Hz at 50Hz/ 54-66Hz at 60Hz (self-adapting) | ||
Input Power Factor | ≥0.99 | ||
Output | Rated Voltage and Accuracy | 380/400/415Vac(1±1%) 3P4W+G | |
Output Frequency | Synchronized with input ; mains frequency ≥ maximum ±10%, output frequency is 50(±0.2%)Hz ; 50/60±0.2% (battery) | ||
Rated Current | 15A | ||
Output Power Factor | 0.9 | ||
Output Harmonic Wave | ≤2% liner ; ≤5% non-liner | ||
Crest Factor | 3: | 1 | |
Output Overload | Load≤110%: 60 mins; Load≤125%: 10 mins; Load≤150%: 1 min; Load≥150% shutdown immediately |
||
Conversion time between Mains Power and Battery | 0ms | ||
Efficiency | normal mode ≥94.5% | ||
Battery | Rated Voltage | default ±192Vdc | |
Quantity | 32-40 | ||
Charging Current | 20A max | ||
Dimension (LxWxH) mm | 865x300x960 | ||
Weight | 85.5kg | ||
Working Temperature | 0℃-40℃ | ||
Altitude | <1500m | ||
Storage | -25~55℃ | ||
Relative Humidity | 0-95% (non-condensing) |