Aplus 42U-420 SNMP USB Communication Ports LCD Display Three Phase Pure Sine Wave Double Conversion Online Modular Ups

Contact me for free samples and coupons.
WhatsAPP:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xDisplay | LCD | Environment Humidity | 5 - 95%, No Condensation |
---|---|---|---|
Rated Capacity | 600KVA | Output Frequency | 50/ 60Hz |
Parallel | 4 Parallel Machines | Battery Type | Sealed Lead Acid |
Input Voltage | 380V | Operating Temperature | 0~40℃ |
Protection | Overload, Short Circuit, Over Voltage, Low Battery | Overload Capacity | 111–125%: 10 Mins, 126–150%: 1 Minute |
Size | 933*860*1801mm | Waveform | Sine Wave |
RM Series Modular UPS
PRODUCT FEATURES
1. Digital Control
All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is more stable and reliable.Each module has built-in automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance.
2. High power density modular design
The capacity of each single module is 30kVA, and the height is 3U; UPS modules can be added and removed online to achieve zero maintenance time.
3. N+X parallel redundancy
The quantity of redundant module can be set accordingly. When the redundant module reaches more than 2 hours, the system availability achieves 99.99% , MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets. A maximum of four cabinets can be parallel, and battery pack can be shared when UPS cabinet in parallel.
4. Color LCD display screen
Super large LCD display with touching function. Chinese/English bilingual option; Single module LCD/LED display.
5. Intelligent Battery Management
Users can set the charging current, constant current, constant voltage and floating charging modes can be automatically and smoothly switched; Battery voltage can be set ±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional)
6. Standard Cabinet Design
The appearance of the standard cabinet is beautiful and generous, which can perfectly match the use environment of the computer room and save the space.
7. Safe and easy to maintain
When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance; Press EPO button to shutdown in emergent situation, and also have REPO function.
8. Intelligent Management
Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMP card (optional), can realize remote monitoring of UPS, relay card is optional.
PARAMETER RM 50-600KVA | ||||||
Model | RM50 300 | RM50 400 | RM50 500 | RM50 600 | ||
Capacity | UPS Cabinet | 50-300kW | 50-400kW | 50-500kW | 50-600kW | |
Power Module | 50kW | |||||
Max Quantity of Module | 6 | 8 | 10 | 12 | ||
Input | Rated Input Voltage | 380/400/415 Vac | ||||
Input Voltage Range | 138-485 Vac | |||||
Wiring | 3P4W+G | |||||
Frequency Range | 40-70Hz | |||||
Input Power Factor | ≥0.99 | |||||
Input Current Harmonic Wave | ≤3% (100% non-linear) | |||||
Bypass Input | Rated Input Voltage | 380/400/415 Vac | ||||
Input Voltage Range | 220 upper limit: 25% (optional +10%,+15%,+20% ) 230 upper limit: 20% (optional +10%,+15% ) 240 upper limit: 15% (optional +10%) Lower limit: -45% (optioinal10%, -20%,-30%) | |||||
Wiring | 3P4W+G | |||||
Bypass synchronization tracing range(Hz) | ± 10% | |||||
Generator | Support | |||||
Power Walking In | Support | |||||
Bypass Flow Backward | Support | |||||
Output | Voltage | 380/400/415 Vac ± 1% | ||||
Power Factor | 1 | |||||
Frequency | Mains mode:± 1%/± 2%/± 4%/± 5%/± 10% settable | |||||
Battery mode: (50/60± 1%)Hz | ||||||
Waveform | Sin Wave | |||||
Crest Factor | 3: | 1 | ||||
Input Current Harmonic Wave | ≤ 2% (100% linear load); ≤ 3% (100% non-linear load) | |||||
Convert time | 0ms | |||||
Efficiency | 96% | |||||
Overload Capacity | 110% load: convert to bypss after 60 mins; 125% load: convert to bypass after 10 mins; 150% load: convert to bypass after 1 min; | |||||
Battery | 20 | |||||
Battery Voltage | 30-50pcs optional, default 36pcs; Optional voltage: ±180Vdc/±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc/ ±252Vdc/ ±264Vdc/ ±276dc/ ±288Vdc/ ±300Vdc; (30/32/34/36/38/40/42/44/46/48/50pcs of battery ) | |||||
Environment | Operating Temperature | 0℃-40℃ | ||||
Storage Temperature | '-25-55℃ ( excluded battery) | |||||
Humidity Range | 0-95% (non-condensing) | |||||
Altitude | <1500m (derating if exceeding 1500m) | |||||
Noise (1 meter distance) | <68dB | <70dB | ||||
Other Functions | Protection Function | Short circuit,overload,over temperature,output overvoltage or undervoltage,battery undervoltage,fan fault alarm,bypass flow backward,anti-thunder | ||||
Alarm Function | Mains abnormal,overload,UPS fault,battery undervoltage and other alarms | |||||
Communicatioin Function | CAN,RS485,network port,dry contact port,parallel port,LBS port,Intelligent slot,temperature sensor port | |||||
Physical Characteristic | Dimension (LxWxH) mm | Cabinet | 600x850x2000 | 1200x850x2000 | 1200x850x2000 | |
Module | 440x620x130 | |||||
Weight (Net Weight) kg | Cabinet | 260 | 280/600 | 645 | 720 | |
Module | 36 | |||||
Operative Standard | YD/T 2165-2010 |