ups uninterruptible power supply
"
Visench OEM 10000VA 20000VA 30000VA 40000VA PF 0.99 On-line Tower Pure Sine Wave UPS
MODEL10K(L15KL)20K(L)30KL40KLPHASE3-phase in/3-phase outCAPACITY10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KV /40KWINPUTHominsl Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC (Ph-N)Voltage Range138~270 VAC(3-phase)@50%load;173~253 VAC(3-phase)@100%load 80~156 VAC(Ph-N) 50%load;100~148 VAC(Ph-N)@100%loadFrequency Range46~54 Hz or 56~64HzPower Factor0.99 @100%LoadOUTPUTQuput Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC(Ph-N)AC Voltage Regulation (Batt.Mode1%Frequency Range
10KVA 15KVA 20KVA 30KVA 40KVA 60KVA Visench Galleon II Rack OEM 3 Phase Ups Systems
MODEL10KL15KL20KL30KL40KL60KLPHASE3-phase in/3-phase outCAPACITY10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KVA/40KW60KVA/6DKWPARALLEL CAPABILITY4INPUTNominal Voltage3400 VAC (3Ph+N)or 208*220/230/240 VAC (Ph-N)Voltage Range190-520 VAC(3-phase)@50%load;305-478 VAC(3-phase)@100%loadFrequency48~54 Hz or 56~84HzPower Factor0.90 @100%loadOUTPUTOutput Voltage3x380Y3801400/415 VAC(3Ph+N)or 208*220/230/240 VAC (Ph-N)3x380Y380/400/415 VAC(3Ph+N)AC Voltage Regulation (Batt.Mode)1
Galleon II Rack OEM UPS 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 3 Phase Online UPS for Alarm Systems
MODEL10KL15KL20KL30KL40KL60KLPHASE3-phase in/3-phase outCAPACITY10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KVA/40KW60KVA/6DKWPARALLEL CAPABILITY4INPUTNominal Voltage3400 VAC (3Ph+N)or 208*220/230/240 VAC (Ph-N)Voltage Range190-520 VAC(3-phase)@50%load;305-478 VAC(3-phase)@100%loadFrequency48~54 Hz or 56~84HzPower Factor0.90 @100%loadOUTPUTOutput Voltage3x380Y3801400/415 VAC(3Ph+N)or 208*220/230/240 VAC (Ph-N)3x380Y380/400/415 VAC(3Ph+N)AC Voltage Regulation (Batt.Mode)1
Data Center Visench Galleon III 3 Phase Pure Sine Wave OEM UPS Rated Capacity 10KVA-40KVA
Product nameGalleon III 3p3pRated Capacity10KVA-40KVAPower Factor0.99Input Voltage3 x 360/380/400/415 VAC(3Ph+N)Frequency40~70 HZOutput Voltage3 x 360*1380*/400/415 VAC (3Ph+N)WaveformPure Sine waveBattery Type12V/9AhPHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph outHarmonic Distortion 2% THD (Linear Load) ; 5 % THD (Non-inear Load)Current Crest Ratio3:1(max.)Battery Mode94.50%Frequency Range46~54Hz or 56~64HzInverter to BypassZeroOperating Temperature0-40CSize(mm
Telecommunications 10000VA 20000VA 30KVA 40KVA Online UPS with Pure Sine Wave Output
Product nameGalleon III 3p3pRated Capacity10KVA-40KVAPower Factor0.99Input Voltage3 x 360/380/400/415 VAC(3Ph+N)Frequency40~70 HZOutput Voltage3 x 360*1380*/400/415 VAC (3Ph+N)WaveformPure Sine waveBattery Type12V/9AhPHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph outHarmonic Distortion 2% THD (Linear Load) ; 5 % THD (Non-inear Load)Current Crest Ratio3:1(max.)Battery Mode94.50%Frequency Range46~54Hz or 56~64HzInverter to BypassZeroOperating Temperature0-40CSize(mm
Visench Fortress 60KVA 80KVA 100KVA 120KVA 180KVA 200KVA 240KVA 300KVA On-line UPS
Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion 2% THD (Linear Load); 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**150%for 200msBATTERY/CHARGERNominal Voltage+/-192V~+1-240V (Selectable)Maximum
7.5KW 3P Single Cooling Air-cooled Precision Air Conditioner for Base Station Power Distribution Room
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCSA1008F3Z3ACSA1013F3Z3ACSA1008F1Z3ACSA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration
Visench CRA Series Room-Level Precision Air Conditioner Floor Standing for Air Supply
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw252540.3Sensible cooling capacity (kw252540.3sensible
Vertiv Liebert GXT5-1000LVRT2UXL Pure Sine Wave 500VA 750VA 1KVA 1500VA 2KVA 3KVA Online Backup UPS For Telecommunications
Product Description Specification itemvalueWarranty1yearPlace of OriginChinaGuangdongBrand NameVertivModel NumberVertiv Liebert GXT5-1000LVRT2UXLElectric Energy1000WhPhaseSingle PhaseProtectionShort CircuitTypeOn-lineApplicationTelecommunicationsProduct nameVertiv Liebert GXT5-1000LVRT2UXLPower level500VA-3000VAProduct typeTower stand UPSInput Voltage120VVoltage range60-150V, 3%Rated frequency40-70HzOutput Voltage110/115/120/125VACOutput power factor1WaveformPure Sine Wave 1