APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries

Place of Origin China
Brand Name APC
Certification CE EAC RCM
Model Number GVSUPS40KHS
Minimum Order Quantity 1
Payment Terms L/C, D/A, D/P, T/T

Contact me for free samples and coupons.

WhatsAPP:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Lead Time Special Order - Call For Quoted Lead Times Main Input Voltage 400 V 3 Phases
Other Input Voltage 380 V 415 V Other Output Voltage Other Output Voltage
Battery Voltage +/- 216...+/- 300 V Weight 688 Kg
Dimensions 2117 X 1000 X 800 Mm Topology Double Conversion Online
Efficiency Up To 96% Display LCD
Communication Ports USB, RS232, SmartSlot Frequency 50/60Hz
Form Factor Tower
Highlight

APC Data Center Galaxy VS UPS

,

Galaxy VS UPS 40kW 400V

You can tick the products you need and communicate with us in the message board.
GVSUPS10KB4HS 10 kVA/10 kW
GVSUPS20KHS 20 kVA/20 kW
GVSUPS30KHS 30 kVA/30 kW
GVSUPS40KHS 40 kVA/40 kW
GVSUPS50KHS 50 kVA/50 kW
GVSUPS60KHS 60 kVA/60 kW
GVSUPS80KHS 80 kVA/80 kW
GVSUPS100KHS 100 kVA/100 kW
GVSUPS120KHS 120 kVA/120 kW
GVSUPS150KHS 150 kVA/150 kW
Leave a Message
GVSUPS10KB4HS 10 kVA/10 kW
Product Description

Features

Galaxy VS is a highly efficient, modular, easy-to-deploy 20 to 150 kW (480 V), 10 to 150 kW (400 V), and 10 to 75 kW (208 V), three-phase uninterruptible power supply that delivers top performance for edge, small, and medium data centers, as well as critical infrastructure in commercial and industrial facilities. Its compact design, high-density technology, N+1 redundancy, and fault-tolerant architecture maximize availability, operational efficiency, and critical load protection, while minimizing total cost of ownership. Thanks to patented technologies, this UPS delivers up to 97% efficiency in normal operating mode and up to 99% in ECOnversion mode, equivalent to 66% higher energy savings. Galaxy VS is EcoStruxure connected to give you peace of mind anytime, anywhere. Smart modular batteries integrated in the UPS cabinet optimize footprint and ensure critical loads have highly predictable runtimes. Start-up service is included to optimize your system’s performance, quality, and safety. With its robust design and industry-leading performance, Galaxy VS is the ideal backbone for your critical infrastructure.

Benefits

Availability Serviceability
  • Multiple levels of service offers - With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.
  • Front-access servicing - Simplifies installation and UPS maintenance while minimizing space requirements.
  • Modular UPS design - Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.
  • EcoStruxure IT Expert - From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries. To learn more, visit ecostruxureit.com.
Total cost of Ownership
  • Wide input voltage range - Designed for harsh electrical environments to save battery life.
  • High efficiency in double conversion mode - Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
  • ECOnversion mode - Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
  • Compact UPS - High-density technology and full front access make this UPS a footprint saver well suited for confined spaces.
  • Robust operation - No power derating in kW up to 40 degrees C or 104 degrees F.
  • Input Power Factor Correction - Minimizes installation costs by enabling the use of smaller generators and cabling.

Specifications

 

Overview
Presentation Highly efficient, easy-to-deploy 40kW, 400V 3-phase uninterruptible power supply (UPS) that brings best-in-class power protection to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Compact design, high-density technology and modular architecture keep total cost of ownership low and operational efficiency at the highest levels. Galaxy VS reduces your energy losses by up to 66% with the patented ECOnversion mode – reaching up to 99% efficiency levels and delivering more energy savings than even our industry-leading 97% efficiency in normal operating mode. The UPS is EcoStruxure-ready to give you peace of mind with cloud-based remote monitoring and management via your smartphone. Includes 5x8 start-up service. For battery runtime details, see the runtime charts published under the Documents tab.
Lead time Usually Ships within 2 Weeks
Main
Main Input Voltage 400 V 3 phases
Other Input Voltage 380 V
415 V
Main Output Voltage 400 V 3 phases
Other Output Voltage 380 V
415 V
Rated power in W 40 kW
Rated power in VA 40 kVA
Output connector type Hard wire 5-wire (3P + N + E) 1
Battery type External battery system
Li-Ion (Lithium-Ion)
VRLA
Provided equipment Dust filter
Installation guide
Integrated network management
Power modules ship installed
Start-up service
Top and bottom cable entry
Batteries & Runtime
Efficiency View Efficiency Graph
action_new_window
Number of battery filled slots 0
Number of battery free slots 0
Battery voltage 384...576 V DC
Discharge battery voltage 307 V DC
Max current discharge 136 A
Battery power in VAH 0 VAh runtime
Extended runtime 0
General
Bypass voltage tolerance +/- 10 %
Max bypass input current 64 A
Redundant No
Physical
Colour White
height 148.5 cm
Width 52.1 cm
Depth 84.7 cm
Net weight 206 kg
USB compatible No
Input
Network frequency 40...70 Hz
Number of input connectors 1 hard wire 4-wire (3P + E)
1 hard wire 5-wire (3P + N + E)
Input voltage limits 340...460 V 400 V
Maximum input current 74 A
Max short time withstand current 65 kA
Input harmonic distortion Less than 3 % for full load
Load power factor From 0.7 leading to 0.7 lagging without any derating
Input Power Factor at Full Load 0.99
Output
Maximum configurable power in W 40 kW
Harmonic distortion Less than 3 %
Output frequency 50 Hz sync to mains
60 Hz sync to mains
60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
Crest factor 2.5
Wave type Sine wave
Output voltage tolerance +/-1% after 50ms
Output harmonic distortion < 1% linear load and < 3% non-linear load
Output overload operation 10 minutes at 125% and 60 seconds at 150%
Bypass type Built-in static bypass
Maximum configurable power in VA 40 kVA
Conformance
Standards CSA C22.2 No 107.3
EN/IEC 62040-1
EN/IEC 62040-2
EN/IEC 62040-3
FCC part 15 class A
IEC 60721-4-2 level 2M2
UL 1778 5th edition
Environmental
ambient air temperature for operation 0…40 °C
Relative humidity 0…95 % non-condensing
Operating altitude 0...3281 ft
Ambient air temperature for storage -25…55 °C
Storage Relative Humidity 10…80 % non-condensing
Storage altitude 0.00…15240.00 m
Acoustic level 65 dBA
heat dissipation 3845.4 Btu/h
IP degree of protection IP21
Communications & Management
Free slots 1
control panel Touch screen LCD user interface
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 168 cm
Package 1 Width 99 cm
Package 1 Length 64 cm
Package 1 Weight 235 kg
Contractual warranty
Warranty 1 year on-site repair or replace with factory authorized Start-Up

 

 

 

APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 0APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 1APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 2APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 3APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 4APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 5APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 6APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 7APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 8APC Data Center And Facility 3 Phase UPS Galaxy VS UPS 40kW 400V For External Batteries 9