xProduct Name | Eaton 93E UPS | Power Level | 100KVA-500KVA |
---|---|---|---|
Rated Voltage | 380Vac/220Vac | Product Type | Tower UPS |
Frequency | 50/60Hz | Audible Noise | 55-73dB |
Crest Factor | 3:1 | ESS Mode | 98% |
Operating Temperature | 0~40ºC | Storage Temperature | -25~55ºC |
Input Voltage | 380Vac/220Vac | Output Voltage | 380Vac/220Vac |
Bypass Voltage | 380Vac | Battery Types | VRLA, AGM, GEL Batteries, Or Eaton Lithium Batteries. |
Charging Time | 8 Hours To Reach 90% Of Full Capacity | Connection | RS-232, Mini-Slot Communication Slot |
Altitude | Less Than 1000 Meters, No Derating | EMC Standard | IEC/EN 62040-2 |
Quality Standard | ISO 9001:2015, ISO 14001:2004 | Certifications | TLC,CQC |
Highlight | Compact Footprint Eaton 93E UPS,Eaton 93E UPS 300kVA,Industrial Online UPS |
Model | Power | |
---|---|---|
93E 100KVA | 100kVA/90kW | |
93E 120KVA | 120kVA/108kW | |
93E 160KVA | 160kVA/144kW | |
93E 200KVA | 200kVA/180kW | |
93E 300KVA | 300kVA/270kW | |
93E 400KVA | 400kVA/360kW |
Eaton 93E UPS 300kVA/270kW 3:3 Phase Industrial Online UPS
Eaton 93E UPS
The Eaton 93E UPS delivers superior power protection for ever-expanding loads in today’s space-constrained data centres. Facilitating a lower total cost of ownership (TCO) through a combination of energy-efficiency, high reliability and a compact footprint the 93E is an ideal solution for small to medium - sized data centres and other applications desiring highly reliable power protection.
The 93E UPS is Eaton's new-generation energy-saving uninterruptible power supply designed to provide a higher level of power protection. This UPS provides reliable power protection solution of a broader power range from 15 kVA to 500 kVA to critical equipment such as IT infrastructure in data centers from small to large, industrial control application systems and laboratory precision instrumentation.
Core features
- Provides rectification and inversion efficiency up to 96% and energy saver mode efficiency up to 99% by using advanced DSP control technology
- As a scalable UPS, utilizes Eaton's patented wireless Hot Sync paralleling technology
- Reduces power consumption with energy saver mode
- Extends battery life by using ABM™ intelligent battery management
- Supports a wide range of optional accessories such as battery cabinets, upper air outlets, parallel management cabinets, upper inlet cabinets and synchronization controllers for better system flexibility and configurability
Eaton 93E UPS 15-500 kVA Technical Specs
Power | |
Ratings | 100kVA/90kW, 120kVA/108kW, 160kVA/144kW, 200kVA/180kW, 300kVA/270kW, 400kVA/360kW, 500kVA/450kW |
Topology | Double-conversion online UPS |
Electrical Input | |
Nominal input voltage | 400/230V, 4 wire (380/415V selectable) |
Input voltage range | -15%, +20% from nominal (400V) at 100% load without depleting battery |
Operating frequency | 50/60 Hz (40 to 72 Hz) |
Input power factor | >0.99 typical |
Input current distortion | ≤5% THD |
Electrical Output | |
Nominal output voltage | 400/230, 4 wire (380/415V selectable) |
Output voltage regulation | ±1% Static; ±5% dynamic at 100% resistive load change, <20 ms response time |
Battery | |
Battery | 192 to 240 Cells (Continual selectable for 15-80kVA) 216/222/228/234/240 Cells (Selectable for 100-500kVA) |
Charging method | ABM Cyclic Charging |
General | |
Efficiency | >98.5% High-efficiency mode (100-300kVA) >99% High-efficiency mode (400-500kVA) >94% Double-conversion mode (15-300kVA) >95% Double-conversion mode (400-500kVA) |
UPS bypass | Automatic on overload or UPS failure |
Parallel technology | Powerware Hot Sync® Technology |
Dimensions W x D x H | 600 x 800 x 1876 (mm) 60-200kVA 1600 x 820 x 1880 (mm) 300/500kVA |
Cabinet rating | IP20 with standard washable dust filters |
Weights without internal battery | 80kVA-245kg, 100kVA-283kg, 120kVA-311kg, 160/200kVA-457kg, 300kVA-860kg, 400kVA-970kg, 500kVA-1020kg |
Overload | 150% for 1 minute, 125% for 10 minutes, >150% for 150ms |
Communications | |
Display | Graphical LCD with blue backlight |
LEDs | (4) LEDs for notice and alarm |
Audible alarms | Yes |
Communication ports | (1) RS-232, (1) USB, (1) EPO |
Communication slots | (2) Mini-slot communication bays |
Environmental | |
Operating temperature | 0ºC to +40ºC Batteries recommended max. +25ºC |
Storage temperature | -25ºC to +55ºC without batteries +15ºC to +25ºC with batteries |
Relative humidity | 5-95%, non-condensing |
Audible noise | 100-120kVA ≤65 dBA at 1m typical 160-200kVA ≤70 dBA at 1m typical 300-400kVA ≤73 dBA at 1m typical 500kVA ≤75dBA at 1m typical |
Altitude | <1000m at +40°C |
Certifications | |
EMI standards | EN55022/EN55024 |
EMC compliance | IEC 62040-2 |
Quality | ISO 9001: 2000 and ISO 14001:1996 |
Communication Accessories | |
Network-MS | Web/SNMP Card |
Modbus-MS | Web/SNMP and Modbus Card |
Relay-MS | Relay (Dry Contact) Card -DB9 Connection |
Industrial Relay | Relay (Dry Contact) Card -Terminal Connection |
116750224-001 | Environmental Monitor Probe (EMP) kit (need to plug into Web/SNMP Card or Web/SNMP and Modbus Card to work) |
System Accessories | |
Battery Cabinets & Battery Circuit Breakers (60-200kVA) | |
Maintenance Bypass Switches (MBS) (100-200kVA, standard on 15-80kVA) | |
Top Cable Entry (60-200kVA, standard on 300-500kVA) | |
System Parallel Modules (60-200kVA) | |
Dual input kit (15-80kVA) | |
IP21 hood (15-200kVA) | |
Rear Chimney (60-200kVA) |