industrial uninterruptible power supply ups
"
8KW 13KW Industrial Air Conditioner Lab Data Center Server Room Cooling Only Category
Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm5*2.5mmOutdoor unit cable (recommended)3*1mmInner and outer unit signal cables (recommended)noneCooling capacity (kW813Sensible cooling
8KW 13KW 17KW 20KW Small Computer Room Floor Standing Industrial Precision Air Conditioner for Server Room
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCSA1008F3Z3ACSA1013F3Z3ACSA1008F1Z3ACSA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration
CNA1008F1Z3A 8KW 13KW 17KW 20KW Room-Based Air-Cooled Industry Precision Air Conditioner for Lab
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCNA1008F3Z3ACNA1013F3Z3ACNA1008F1Z3ACNA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration
Vertiv Liebert GXT5-3000IRT2UXL 3000Va Online Industrial UPS for Telecommunications
Product Description Specification itemvalueWarranty1yearPlace of OriginChinaGuangdongBrand NameVertivModel NumberVertiv Liebert GXT5-3000IRT2UXLElectric Energy3000WhPhaseSingle PhaseProtectionShort CircuitTypeOn-lineApplicationTelecommunicationsProduct nameVertiv Liebert GXT5-3000IRT2UXLPower level1500VA-10KVAProduct typeTower stand UPSInput Voltage230VVoltage range115-288V, 3%Rated frequency40-70HzOutput Voltage200/208/220/230/240VACOutput power factor1WaveformPure Sine
Mounting Floor Standing Industrial Air Conditioner for Lab Server Room and Data Center
Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm5*2.5mmOutdoor unit cable (recommended)3*1mmInner and outer unit signal cables (recommended)noneCooling capacity (kW813Sensible cooling
Vertiv Liebert GXT5-6000MVRT4UXLN 5KW 6KW 8KW 10KW Industrial Online UPS for Data Center
Product Description Specification itemvalueWarranty1yearPlace of OriginChinaGuangdongBrand NameVertivModel NumberVertiv Liebert GXT5-6000MVRT4UXLNElectric Energy6000WhPhaseSingle PhaseProtectionShort CircuitTypeOn-lineApplicationTelecommunicationsProduct nameVertiv Liebert GXT5-6000MVRT4UXLNPower level5KVA-10KVAProduct typeTower stand UPSInput Voltage176 - 280 VACVoltage range176 - 280 VACRated frequency40-70HzOutput Voltage208/120VACOutput power factor1WaveformPure Sine Wave
High Industrial Precision Air Conditioner 8KW 13KW for Lab Data Center Server Room
Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm5*2.5mmOutdoor unit cable (recommended)3*1mmInner and outer unit signal cables (recommended)noneCooling capacity (kW813Sensible cooling
130kg CSA1008F1Z3A 8KW 13KW 17KW 20KW Room-Based Air-Cooled Industry Precision Air Conditioner for Data Center
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCSA1008F3Z3ACSA1013F3Z3ACSA1008F1Z3ACSA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration
High Industrial Precision Air Conditioning for Server Room CSA1008F1Z3A 8KW 13KW 17KW 20KW
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCSA1008F3Z3ACSA1013F3Z3ACSA1008F1Z3ACSA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration