data centers lead acid battery
"
Data Center Santak Castle 3C3 HD UPS 200kVA 300kVA 400kVA 500kVA 600kVA Internal Modular Design
Santak Castle 3C3 HD UPS Santak Castle Series UPS CASTLE 3C3 HD 20-200kVA CASTLE 3C3 HD 20-200K 3C3 HD UPS is the new generation three phase tower UPS, which adopts the most advanced power electronics and digital signal control and protection technology. It performs higher efficiency, higher performance, and more convenient operation, and can provide users with high quality power supply guarantee in various industries. Typical application environment Small and medium-sized
3Phase online Data Center Santak Castle 3C3 HD UPS 200kVA 300kVA 400kVA 500kVA 600kVA Internal Modular Design
Santak Castle 3C3 HD UPS Santak Castle Series UPS CASTLE 3C3 HD 20-200kVA CASTLE 3C3 HD 20-200K 3C3 HD UPS is the new generation three phase tower UPS, which adopts the most advanced power electronics and digital signal control and protection technology. It performs higher efficiency, higher performance, and more convenient operation, and can provide users with high quality power supply guarantee in various industries. Typical application environment Small and medium-sized
7.5KVA 7.5KW 7500W 7500VA Single Phase Low Frequency Industrial Digital UPS for Data Center
MODELGiant Elite 6k(L)Giant Elite 7.5k(L)Giant Elite 10k(L)PHASESingle phase with groundCAPACITY6KVA/4.8KW7.5KVA/6KW10KVA/8KWINPUTNominal Voltage208VAC/220VAC/230VACVoltage Range165VAC~285VAC @16 pcs of batteries;185VAC~285VAC @18 pcs of batteriesFrequenc40 Hz~55 Hz @50Hz system;56 Hz~64 Hz @60Hz systemOUTPUTOutout Voltage208VAC/220VAC/230VACVoltage Regulation1%Frequency Range (Synchronized Range)45Hz~55 Hz or 56 Hz~64 HzFrequency Range (Batt.Mode)50 Hz0.1 Hz or 60Hz0.1
Vertiv liebert CRV CW 30KW 60KW Precision Type air Conditioner Data Center Cooling System For Data Center
Product Description Specification itemvalueApplicable IndustriesManufacturing PlantConditionNewTypePrecision Industrial Air ConditionerPlace of OriginChinaGuangdongBrand NameVertiv liebertOperating Voltage380/400 VACMountingFloor StandingWarranty1 YearDimension(L*W*H)300*1100*2000 600*1100*2000 mmKey Selling PointsHigh Safety LevelAirflow5900 11000 12200 m/hMachinery Test ReportProvidedVideo outgoing-inspectionProvidedWarranty of core components1 YearCore ComponentsPressure
Visench Winner Pro 1KR Rack OEM UPS 1KVA 1KW 1000W 1 Phase Online UPS for Data Center
Product nameWinner Pro RackRated Capacity1KVA -10KVAPower Factor0.99Input Voltage208/220/230/240VACFrequency40Hz-70HzOutput Voltage208/220/230/240VACWaveformPure Sine waveBattery Type12V/9AHPHASESingle phase with grounHarmonic Distortion 3 % THD (Linear Load),Harmonic DistortionCurrent Crest Ratio3:01Voltage Regulatior1%Frequency Range47~ 53 Hz or 57~ 63 HzInverter to Bypass4 ms (Typical)Typical Recharge Time4 hours recover to 90% capacitySize(mm)310x438x88/410x438x88
10KVA-40KVA Rated Capacity Visench Galleon ll 3 Phase Tower UPS for Data Center
MODEL10K(L15KL)20K(L)30KL40KLPHASE3-phase in/3-phase outCAPACITY10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KV /40KWINPUTHominsl Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC (Ph-N)Voltage Range138~270 VAC(3-phase)@50%load;173~253 VAC(3-phase)@100%load 80~156 VAC(Ph-N) 50%load;100~148 VAC(Ph-N)@100%loadFrequency Range46~54 Hz or 56~64HzPower Factor0.99 @100%LoadOUTPUTQuput Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC(Ph-N)AC Voltage Regulation (Batt.Mode1%Frequency Range
30KVA 30KW 30000W 30000VA Pure Sine Wave Online Ups for Data Center Visench Galleon III
Product nameGalleon III 3p3pRated Capacity10KVA-40KVAPower Factor0.99Input Voltage3 x 360/380/400/415 VAC(3Ph+N)Frequency40~70 HZOutput Voltage3 x 360*1380*/400/415 VAC (3Ph+N)WaveformPure Sine waveBattery Type12V/9AhPHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph outHarmonic Distortion 2% THD (Linear Load) ; 5 % THD (Non-inear Load)Current Crest Ratio3:1(max.)Battery Mode94.50%Frequency Range46~54Hz or 56~64HzInverter to BypassZeroOperating Temperature0-40CSize(mm
Data Center Visench Galleon III 3 Phase Pure Sine Wave OEM UPS Rated Capacity 10KVA-40KVA
Product nameGalleon III 3p3pRated Capacity10KVA-40KVAPower Factor0.99Input Voltage3 x 360/380/400/415 VAC(3Ph+N)Frequency40~70 HZOutput Voltage3 x 360*1380*/400/415 VAC (3Ph+N)WaveformPure Sine waveBattery Type12V/9AhPHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph outHarmonic Distortion 2% THD (Linear Load) ; 5 % THD (Non-inear Load)Current Crest Ratio3:1(max.)Battery Mode94.50%Frequency Range46~54Hz or 56~64HzInverter to BypassZeroOperating Temperature0-40CSize(mm
Eaton Industrial UPS 400KVA Eaton 3 Phase UPS For Data Center
Eaton 93E UPS The Eaton 93E UPS delivers superior power protection for ever-expanding loads in todays space-constrained data centres. Facilitating a lower total cost of ownership (TCO) through a combination of energy-efficiency, high reliability and a compact footprint the 93E is an ideal solution for small to medium - sized data centres and other applications desiring highly reliable power protection. 400kVA UPS with internal MBS & Backfeed contactor, battery cabinet not